Description
The VRS – Variable Range Simulator is a system used for range simulation
Laser Designator Tester and Laser Range Finder Tester (LRF) for accuracy and functionality.
The VRS can test LRFs operating in a broad range of wavelengths from 850nm to 1570nm, with the option of
selecting up to three discrete wavelengths to be incorporated into the VRS.
Download Brochure
Download brochures VRS-SRS (891KB)
- Simulate ranges, laser pulse width and energy per pulse
- Simulation modes for constant ranges or dynamic targets
- Can be activated by either optical pulse or electronic trigger
- Superior ranging accuracy
- Includes: CI-Systems S/W, laser for alignment via a visible channel, mechanical adjustable jig for holding the optic fibers
Optional Features of laser range finder tester and designator tester:
- Dynamic targets can be simulated with up to 15,000 lines stored in one file
- Select up to three independent laser sources / wavelengths
- Stand alone unit or 19” Rack mountable
VRS | VRS-EX | |
Wavelengths | from 850 nm to 1570 nm (up to 3 wavelengths per VRS unit) | |
Input trigger – optical type | Single laser pulse available at any wavelengths between 850 nm to 1570 nm | |
Input trigger – electronic type | TTL | |
Range Simulation and range accuracy (*) | from 120m to 30km ± 1m | from 80m to 60km ± 0.5m |
Range resolution | 1 m | 0.5 m |
Pulse width and pulse width accuracy | 12 – 80 nsec ±1nsec | 6 – 160 nsec ±1nsec |
Laser power output | 20 mW @ fiber end (other optional) | |
Laser power output resolution | 0.1 dB | |
Dynamic output power range | 20 dB (non-linear) electronic control (optical filters can be added by the user) | |
Static (constant) target simulation | Up to two targets | Up to three targets |
Dynamic target simulation | Up to two targets | |
Pulse rate | 4.8 kHz (max) | |
Memory | Up to 15,000 lines stored in one CSV file | |
Interlock control feature | “Dry contact” circuitry | |
Visible alignment laser | 630 nm | |
Communication type | RS-232, USB communication by serial adaptor | |
Input power | 110/220 VAC – 1.25 A | |
Operating temperature | 0 °C to 40 °C |