Workswell SAFETIS Stainless Steel thermal camera

specially constructed for the fast detection of the risk of flare-up before the occurrence of fire. It is one of the components of the SAFETIS system, and as results from the name, the SAFETIS Stainless Steel camera is designed for outdoor installations

The high level of IP67 coverage and mechanical strength ensure sufficient resistance of the thermal camera, which also includes within demanding outdoor conditions. The thermal camera is fully radiometric with a resolution of 336 x 256 pixels or 640 x 512 pixels and with an image frequency of 9 Hz, 30 Hz or 60 Hz.

The SAFETIS Stainless Steel thermal camera as a fully radiometric camera, enables, in addition to the detection of the risk of the occurrence or the presence of the fire, also with high precision to change the surface temperature (the uncertainty of measurement is 2°C ± 2%). Information about the surface temperature is important for the evaluation of the risk of flare-up as temperature trends are the main information used to evaluate the risk of the occurrence of fire. Due to the high-temperature sensitivity, the system can record the minimum changes in the temperature. The system’s intelligence is, according to the setting of the operator and the adaptation of the system, able to prevent most false alarms.

Upon an alarm, the SMARTIS stainless steel thermal camera informs the master system through one of seven digital outputs (type of open collector). Individual outputs can be assigned to various events, areas and types of alarms.

SAFETIS thermal cameras come with two temperature ranges, i.e. -25 °C to 150 °C, or -40 °C to +550 °C, with an external filter then +50 °C to 1,000 °C or +400 °C to 1,500 °C

Wide range of lenses

To be able to adapt the thermal camera for the stated application, the offer includes four lens with fields of vision 90°x69°, 69°x56°, 45°x37° and 32°x26° for 640 x 512 px a 45°x35°, 35°x27°, 25°x19° a 17°x13° for 335 x 256 px. Depending on the lens used, it is possible to monitor, for example, distant objects or, on the contrary, the surface of a nearby object with a wider area (for example, warehouse, surface of a conveyor or weighing pit, etc.).

The size of the recorded area, depending on the distance and the type of lens used, can be verified n the calculator for the field of vision.

SAFETIS system components

New Workswell SAFETIS Stainless Steel thermal camera for the fast detection of the risk of flare-up, IP 67 protectionThe following thermal cameras are included in the SAFETIS fire detection camera system:

  • SAFETIS Outdoor, i.e. exterior version of the cover with high level of protection
  • SAFETIS Indoor, i.e. interior version and also
  • SAFETIS Outdoor Pan-Tilt, i.e. version with high level of IP 67 coverage and PTZ positioning system.

In addition, the offer includes a further two special thermal cameras. One of these is SAFETIS Stainless Steel thermal camera. The protection cover of this camera is designed to provide resistance under external conditions in special fields of industry where there are highly corrosive influences or the occurrence of aluminium is prohibited. This camera is adapted for demanding outdoor use with a high level of coverage.

The second special thermal camera is SAFETIS EX-proof – a specially modified cover enables to install the camera in an environment with the risk of explosion where it is necessary to comply with strict standards. This camera has ATEX certification.

The principle of fast detection of fire detection by SAFETIS thermal cameras

fire detection stagesThe principle of the function of the fast detection of fire or the risk of flare-up by SAFETIS thermal cameras is based on the continuous measurement of heating and temperature changes in the recorded scene. Temperature trends are consequently evaluated and using specific algorithms, the potential risk of flare-up is stated while false alarms are eliminated within the necessary extent. The SAFETIS system is able to react much earlier than all other systems that indicate the symptoms of an already originated fire.

Gradual heating

Flames and smoke have not started yet. There is only the risk of gradual warming. Despite the fact that the smoke detectors do not respond, the SAFETIS system records small changes in heating and can react early.

Smoke generation

Smoke detectors respond in this phase, i.e. at the time when the smoke is generated. However, this is a risky phase where the rapid escalation of a destructive fire can occur. The SAFETIS system would have reacted a long time ago to the origination of this event.

Flare-up

In this phase, flames are visible and smoke is generated. Special CCTV cameras and the smoke detectors respond to this. Usually, this is too late and the loss of property or life frequently occurs.

Typical applications of the SAFETIS fire detection camera system

Some of the typical applications of the SAFETIS fire detection camera system are used to monitor the following areas:

  • Industrial warehouses
  • Ammunition warehouses
  • Coal warehouses and conveyors
  • Power plants and electric energy distribution systems
  • Agricultural warehouses, food warehouses
  • ATEX environment
  • Depots and incineration plants, warehouses for hazardous waste
  • Conveyor belts
  • Chemical and industrial plants
  • Cement plants
  • Monitoring of perimeters

Central unit or Web-server

Each SAFETIS stainless steel thermal camera can be communicated with through a built-in Web-server. This server provides a basic image stream as well as options for advanced configuration and setting all necessary parameters.

The multi-camera system can be connected through the SAFETIS Control Unit. This unit enables to interconnect up to 16 SAFETIS thermal fire detection cameras with any construction. Cameras can be configured from this central unit, as well as to show alarms, etc. More information about the central unit can be found on the separate product page SAFETIS Control Unit.

Technical parametersDownload

SAFETIS Indoor specification table
Resolution336 x 256 pixels640 x 512 pixels
Image frequency9 Hz, 30 Hz or 60 Hz9 Hz or 30 Hz
Temperature ranges-25°C to +150 °C
 -40°C to +550 °C
 Optional extended temperature range +50 °C to +1 000 °C (filter)
 Optional extended temperature range +400 °C to +1 500 °C (filter)
Temperature sensitivity0.05 °C (50 mK)
Spectral range7.5 – 13.5 µm
Detector typeUncooled VOx microbolometer
FocusContinuous manual (fixed focusable, min focus distance depends on lens)
CalibrationYes, including calibration certificate
Web serverYes, integrated with additional early fire detection functions
FOV/Focal length 640 x 512iFOVAccuracyPixel size
FOV 90° x 69° / 7.5 mm2.267 mrad±2 % or ±2 °C2.3 mm from 1 meter
FOV 69° x 56° / 9 mm1.889 mrad±2 % or ±2 °C1.9 mm from 1 meter
FOV 45° x 37° / 13 mm1.308 mrad±2 % or ±2 °C1.3 mm from 1 meter
FOV 32° x 26° / 19 mm0.895 mrad±2 % or ±2 °C0.9 mm from 1 meter
FOV/Focal length 336 x 256iFOVAccuracyPixel size
FOV 45° x 35° / 6.8 mm2.267 mrad±2 % or ±2 °C2.3 mm from 1 meter
FOV 35° x 27° / 9 mm1.889 mrad±2 % or ±2 °C1.9 mm from 1 meter
FOV 25° x 19° / 13mm1.308 mrad±2 % or ±2 °C1.3 mm from 1 meter
FOV 17° x 13° / 19mm0.895 mrad±2 % or ±2 °C0.9 mm from 1 meter
SAFETIS Outdoor built-in functions (integrated web-server)
Camera configurationBuilt-in web-server for easy and fast sensor configuration, Google Chrome, Safari, Explorer or Firefox browser compatible, no external software required
Monitoring and alarmingExtreme detection, MAX/MIN evaluation, Dynamic/Static measurement, User Control Table (Logical rules and PLC connection), Selectable digital output for specific ROI result (OR/AND operators)
VisualizationReal-time video streaming, Pallet settings, Overlay elements, Digital zooming, Numeric and statistical indicators, Input and Output overview panel
Image correctionNon-Uniformity Correction asynchronous/synchronous/triggerable
ROIUser definable measurement area (Point, Line, Polyline, Rect., Polygon, Circle) Multiple product selection for ROI presets (Manual or via Ethernet)
OthersReal-time Clock, Emissivity correction, Multiple languages
Camera configurationCamera is completely configured via SAFETIS Control software that is preinstalled on SAFETIS Control Unit
Number of camerasUp to 16 cameras connected to single SAFETIS Control unit
Monitoring and alarmingAdvanced analytics functions, Extreme detection, MAX/MIN evaluation, Dynamic/Static measurements, User Control Table (Logical rules for PLC connection), Selectable digital outputs for specific ROI measurement analysis
Advanced analytics functionsYes, eliminating of non-alarm triggers, eliminating of moving objects etc.
Graphical alarm visualizationYes
RecordingPre-alarm recording function allows to start recording before the alarms appear
Image recordingYes
Fully radiometric recordingYes
LoggingYes
VisualizationReal-time video streaming from up to 16 cameras, Pallet settings, Overlay elements, Digital zooming, Numeric and statistical indicators
Visualization on desktopVisualization can be reorganized according to customer wish
Graphs visualization from ROIYes
ROIUser definable measurement area (Point, Line, Polyline, Rect., Polygon, Circle)
Digital outputsUp to 15 digital outputs (7 on the camera, 8 on the SAFETIS Control Unit)
Network and I/O connectivity 
Network connectivityEthernet for streaming and control (IEEE 802.3) Ethernet 100Mb/sec, RJ-45, Metal cable gland protection
Digital outputs on the camera7 x Isolated open collector output (max 40 VDC), M12 circular thread
Environmental data, dimensions and power supply
IP protection (Encapsulation)EN60529 (IP66/IP67) with cable glands
Operating temperature-25°C to +50°C
Automatic heatersYes, including clearing the window from ice
Storage temperature-40°C to +70°C
Humidity5% to 95% non-condensing
Dimensions and weight460 x 182 x 164 mm, 7.3 kg
Supply input230 Vac, < 20 W, M12 circular thread
MountingMore information in the housing datasheet